Under the 2021 International Residential Code (IRC), section R311.7, a stair in a house can have risers up to 7-3/4" high and treads at least 10" deep, a single flight can rise at most 151" before it needs a landing, and the stair must be at least 36" wide with 6' 8" of headroom. These values are being verified against the official ICC text, and your local code may differ: many states and towns adopt the IRC with amendments, and your building department has the final word.
This guide is a plain summary to plan a stair, not a copy of the code. Read the sections on the ICC site for the exact wording and exceptions.
The main IRC 2021 stair limits
| Rule | Limit (one- and two-family dwellings) | Section |
|---|---|---|
| Riser height | 7-3/4" maximum | R311.7.5.1 |
| Riser variation | Largest riser no more than 3/8" above the smallest in a flight | R311.7.5.1 |
| Tread depth | 10" minimum, nosing to nosing | R311.7.5.2 |
| Tread variation | Largest tread no more than 3/8" deeper than the smallest | R311.7.5.2 |
| Rise of one flight | 151" maximum between floors or landings | R311.7.3 |
| Width | 36" minimum clear above the handrail height | R311.7.1 |
| Headroom | 6' 8" minimum, measured from the nosing line | R311.7.2 |
| Nosing | 3/4" to 1-1/4" where treads are less than 11" deep | R311.7.5.3 |
| Handrail | On at least one side of a flight with four or more risers | R311.7.8 |
| Handrail height | 34" to 38" above the nosings | R311.7.8.1 |
Summary of IRC 2021 R311.7, being verified against the ICC text, November 23, 2026.
Riser height: R311.7.5.1
The riser is the vertical height of one step, measured from the top of one tread to the top of the next. The IRC limit is 7-3/4". All risers in a flight must be close to equal: the tallest can be no more than 3/8" taller than the shortest. That rule is why you divide the total rise into equal risers instead of cutting the last step short.
To find the risers, divide the total rise by 7.75 and round up. For a 9 ft (108") rise: 108 ÷ 7.75 = 13.9, so 14 risers, each 108 ÷ 14 = 7.71", about 7-11/16".
Tread depth: R311.7.5.2
The tread depth is measured horizontally from the edge of one nosing to the edge of the next. The IRC minimum is 10". Like risers, the deepest tread can be no more than 3/8" deeper than the shallowest in the flight. Winder treads (the wedge-shaped ones that turn a corner) have their own rule in R311.7.5.2.1.
A stair always has one tread fewer than risers, because the top riser steps onto the floor above. The 14-riser stair above has 13 treads, so at 10" each the total run is 130", or 10' 10".
Rise of one flight: R311.7.3
One flight can rise no more than 151" (12' 7") between floor levels or landings. A taller stair needs a landing partway. A 160" rise, for example, is over the limit for a single flight.
Width and headroom: R311.7.1 and R311.7.2
- Width: at least 36" clear above the handrail height. Handrails can project into that width by a limited amount on each side.
- Headroom: at least 6' 8" measured vertically from a sloped line along the tread nosings to the ceiling or anything above, such as a beam or a soffit. Check headroom early on basement stairs, where a floor joist or a duct often sits right over the stair.
Nosings: R311.7.5.3
Where treads are less than 11" deep, the code calls for a nosing that projects between 3/4" and 1-1/4" past the riser below. The nosing gives the foot more room on a shallow tread. On a stair with 11" or deeper treads, a nosing is not required by this rule.
Landings and handrails: R311.7.6 and R311.7.8
- Landings: there must be a floor or landing at the top and bottom of each stair, at least as wide as the stair and at least 36" deep in the direction of travel. The code has exceptions, for example at the top of an interior flight when no door swings over the stairs.
- Handrails: a flight with four or more risers needs a handrail on at least one side, 34" to 38" high measured vertically from the line of the nosings, graspable and continuous for the length of the flight.
Guards (the railings on the open side of a stair or a deck) are a separate section, R312.
A worked stair, checked
| Step | 108" total rise |
|---|---|
| Risers | 108 ÷ 7.75 = 13.9, round up to 14 |
| Riser height | 108 ÷ 14 = 7.71", about 7-11/16" (passes 7-3/4") |
| Treads | 13 at 10" (passes 10") |
| Total run | 130" |
| Stringer length | √(108² + 130²) = 169", about 14' 1" |
| Angle | about 39.7° |
| Flight rise | 108" (passes 151") |
The stair calculator does this from the total rise and shows the three checks, and the stair stringer calculator adds the framing-square marks, throat depth and the board to buy.
What the Stud app checks
The stair code checks in the Stud app test three limits: riser height of 7-3/4" or less (R311.7.5.1), tread depth of 10" or more (R311.7.5.2) and the rise of one flight of 151" or less (R311.7.3). Width, headroom, nosings, landings and handrails depend on the building, so check them on your plans. The app is free and works offline on iPhone.
Frequently asked questions
What is the maximum riser height under the IRC?
7-3/4" under IRC 2021 R311.7.5.1, with no more than 3/8" between the tallest and shortest riser in a flight. The value is being verified against the ICC text; local codes may differ.
What is the minimum tread depth for residential stairs?
10" under IRC 2021 R311.7.5.2, measured from nosing to nosing.
How tall can a flight of stairs be without a landing?
151" (12' 7") of vertical rise under R311.7.3.
When does a stair need a handrail?
Under R311.7.8, a flight with four or more risers needs a handrail on at least one side, 34" to 38" high.
Does my town follow the IRC exactly?
Not always. Many states and towns adopt the IRC with local amendments. Ask your building department which edition and changes apply.